Summary0026319: Incorrect work of mfc OCAF sample
DescriptionIt is impossible to save/load .std documents in mfs OCAF sample.
Steps To ReproduceBuild mfc samples
Run OCAF sample
Try to load any .std document -> exception
Try to save any shape to .std document -> exception
TagsNo tags attached.
Test case number

Activities

abv

2015-06-05 15:01

manager   ~0041983

Are you using current master? there should be no support of standard persistence -- it has been removed recently! Binary or Xml variants should be used inetead

ski

2015-06-05 15:35

developer   ~0041985

It seems that mfc sample OCAF was not correctly updated, it is possible to try open .std file and SaveAs .std file.

szy

2015-09-17 15:01

manager   ~0045803

Usage of 'std' format is eliminated.
At the moment two formats - XmlOcaf & BinOcaf - are supported only.

bugmaster

2015-09-17 15:15

administrator   ~0045808

Issue has been fixed by correction for issue 0026637

Issue History

Date Modified Username Field Change
2015-06-05 14:10 ski New Issue
2015-06-05 14:10 ski Assigned To => szy
2015-06-05 14:10 ski Status new => assigned
2015-06-05 15:01 abv Note Added: 0041983
2015-06-05 15:35 ski Note Added: 0041985
2015-09-17 15:01 szy Note Added: 0045803
2015-09-17 15:01 szy Assigned To szy => bugmaster
2015-09-17 15:01 szy Resolution open => no change required
2015-09-17 15:14 bugmaster Status assigned => resolved
2015-09-17 15:14 bugmaster Status resolved => reviewed
2015-09-17 15:15 bugmaster Note Added: 0045808
2015-09-17 15:15 bugmaster Status reviewed => verified
2016-04-20 15:44 aiv Fixed in Version => 7.0.0