View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0031971 | Open CASCADE | OCCT:Data Exchange | public | 2020-12-02 12:29 | 2021-09-04 15:51 |
| Reporter | kgv | Assigned To | bugmaster | ||
| Priority | normal | Severity | tweak | ||
| Status | closed | Resolution | fixed | ||
| Product Version | 6.3.1 | ||||
| Target Version | 7.6.0 | Fixed in Version | 7.6.0 | ||
| Summary | 0031971: Data Exchange, STEP reader - error messages should not be in French | ||||
| Description | STEP reader output might contain confusing messages in French:
*** ERR StepReaderData *** Pour Entite #5
Type:PRODUCT_DEFINITION Param.n0 4: 0000009 Non trouve
Report : 1 unknown entities.
Status from reading STEP file c:/workssd/test2.stp : file read
Count of shapes produced : 1
It is desired translating these messages into English. | ||||
| Tags | No tags attached. | ||||
| Test case number | Not required | ||||
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2020-12-02 12:29 | kgv | New Issue | |
| 2020-12-02 12:29 | kgv | Assigned To | => gka |
| 2020-12-02 12:29 | kgv | Relationship added | related to 0031970 |
| 2020-12-02 12:29 | kgv | Assigned To | gka => dpasukhi |
| 2020-12-02 12:29 | kgv | Severity | minor => tweak |
| 2020-12-02 12:29 | kgv | Status | new => assigned |
| 2021-02-06 20:34 | dpasukhi | Note Added: 0098744 | |
| 2021-02-06 20:34 | dpasukhi | Assigned To | dpasukhi => bugmaster |
| 2021-02-06 20:34 | dpasukhi | Status | assigned => feedback |
| 2021-02-15 13:38 | bugmaster | Status | feedback => verified |
| 2021-02-15 13:38 | bugmaster | Resolution | open => fixed |
| 2021-09-04 15:51 |
|
Test case number | => Not required |