Open CASCADE Technology 7.8.0
Public Member Functions
Interface_ReaderModule Class Referenceabstract

Defines unitary operations required to read an Entity from a File (see FileReaderData, FileReaderTool), under control of a FileReaderTool. The initial creation is performed by a GeneralModule (set in GeneralLib). Then, which remains is Loading data from the FileReaderData to the Entity. More...

#include <Interface_ReaderModule.hxx>

Inheritance diagram for Interface_ReaderModule:
Inheritance graph
[legend]

Public Member Functions

virtual Standard_Integer CaseNum (const Handle< Interface_FileReaderData > &data, const Standard_Integer num) const =0
 Translates the type of record <num> in <data> to a positive Case Number. If Recognition fails, must return 0.
 
virtual void Read (const Standard_Integer casenum, const Handle< Interface_FileReaderData > &data, const Standard_Integer num, Handle< Interface_Check > &ach, const Handle< Standard_Transient > &ent) const =0
 Performs the effective loading from <data>, record <num>, to the Entity <ent> formerly created In case of Error or Warning, fills <ach> with messages Remark that the Case Number comes from translating a record.
 
virtual Standard_Boolean NewRead (const Standard_Integer casenum, const Handle< Interface_FileReaderData > &data, const Standard_Integer num, Handle< Interface_Check > &ach, Handle< Standard_Transient > &ent) const
 Specific operator (create+read) defaulted to do nothing. It can be redefined when it is not possible to work in two steps (NewVoid then Read). This occurs when no default constructor is defined : hence the result <ent> must be created with an effective definition from the reader. Remark : if NewRead is defined, Copy has nothing to do.
 
- Public Member Functions inherited from Standard_Transient
 Standard_Transient ()
 Empty constructor.
 
 Standard_Transient (const Standard_Transient &)
 Copy constructor – does nothing.
 
Standard_Transientoperator= (const Standard_Transient &)
 Assignment operator, needed to avoid copying reference counter.
 
virtual ~Standard_Transient ()
 Destructor must be virtual.
 
virtual const opencascade::handle< Standard_Type > & DynamicType () const
 Returns a type descriptor about this object.
 
Standard_Boolean IsInstance (const opencascade::handle< Standard_Type > &theType) const
 Returns a true value if this is an instance of Type.
 
Standard_Boolean IsInstance (const Standard_CString theTypeName) const
 Returns a true value if this is an instance of TypeName.
 
Standard_Boolean IsKind (const opencascade::handle< Standard_Type > &theType) const
 Returns true if this is an instance of Type or an instance of any class that inherits from Type. Note that multiple inheritance is not supported by OCCT RTTI mechanism.
 
Standard_Boolean IsKind (const Standard_CString theTypeName) const
 Returns true if this is an instance of TypeName or an instance of any class that inherits from TypeName. Note that multiple inheritance is not supported by OCCT RTTI mechanism.
 
Standard_TransientThis () const
 Returns non-const pointer to this object (like const_cast). For protection against creating handle to objects allocated in stack or call from constructor, it will raise exception Standard_ProgramError if reference counter is zero.
 
Standard_Integer GetRefCount () const noexcept
 Get the reference counter of this object.
 
void IncrementRefCounter () noexcept
 Increments the reference counter of this object.
 
Standard_Integer DecrementRefCounter () noexcept
 Decrements the reference counter of this object; returns the decremented value.
 
virtual void Delete () const
 Memory deallocator for transient classes.
 

Additional Inherited Members

- Public Types inherited from Standard_Transient
typedef void base_type
 Returns a type descriptor about this object.
 
- Static Public Member Functions inherited from Standard_Transient
static constexpr const charget_type_name ()
 Returns a type descriptor about this object.
 
static const opencascade::handle< Standard_Type > & get_type_descriptor ()
 Returns type descriptor of Standard_Transient class.
 

Detailed Description

Defines unitary operations required to read an Entity from a File (see FileReaderData, FileReaderTool), under control of a FileReaderTool. The initial creation is performed by a GeneralModule (set in GeneralLib). Then, which remains is Loading data from the FileReaderData to the Entity.

To work, a GeneralModule has formerly recognized the Type read from FileReaderData as a positive Case Number, then the ReaderModule reads it according to this Case Number

Member Function Documentation

◆ CaseNum()

virtual Standard_Integer Interface_ReaderModule::CaseNum ( const Handle< Interface_FileReaderData > &  data,
const Standard_Integer  num 
) const
pure virtual

Translates the type of record <num> in <data> to a positive Case Number. If Recognition fails, must return 0.

Implemented in IGESData_ReadWriteModule, and StepData_ReadWriteModule.

◆ NewRead()

virtual Standard_Boolean Interface_ReaderModule::NewRead ( const Standard_Integer  casenum,
const Handle< Interface_FileReaderData > &  data,
const Standard_Integer  num,
Handle< Interface_Check > &  ach,
Handle< Standard_Transient > &  ent 
) const
virtual

Specific operator (create+read) defaulted to do nothing. It can be redefined when it is not possible to work in two steps (NewVoid then Read). This occurs when no default constructor is defined : hence the result <ent> must be created with an effective definition from the reader. Remark : if NewRead is defined, Copy has nothing to do.

Returns True if it has produced something, false else. If nothing was produced, <ach> should be filled : it will be treated as "Unrecognized case" by reader tool.

◆ Read()

virtual void Interface_ReaderModule::Read ( const Standard_Integer  casenum,
const Handle< Interface_FileReaderData > &  data,
const Standard_Integer  num,
Handle< Interface_Check > &  ach,
const Handle< Standard_Transient > &  ent 
) const
pure virtual

Performs the effective loading from <data>, record <num>, to the Entity <ent> formerly created In case of Error or Warning, fills <ach> with messages Remark that the Case Number comes from translating a record.

Implemented in IGESData_ReadWriteModule, and StepData_ReadWriteModule.


The documentation for this class was generated from the following file: